Use
Fire door -
Applications
Residential, commercial -
Characteristics
Tested to EN fire protection guidelines, selection of drive motors and glass types, fireproof -
Certification
Tested in accordance with EN 1634-1 | Fire resistance class EI30/EI60/EI90 | Emergency exit door in accordance with EN 179 / 1125 | Swiss fire protection applications
The higher safety requirements in a building increasingly require the functional interaction of various fire protection requirements. So that technically demanding combinations also meet aesthetic requirements, individual door profiles in the proven fire protection system Janisol 2 EI30 from Jansen have been expanded with an installation depth of 70 mm. In this way, transparent Janisol C4 EI60 fire-resistant partitions - in extreme cases even EI90 fire-resistant partitions- can be combined with Janisol 2 EI30 without problems.
Materials/Surface Finishes
- Uncoated steel or hot-galvanized strip steel, suitable for powder coating or stove-enameling
Element Types
- Single and double-leaf doors with fixed side frames and/or transom window
Equipment
- Steel and stainless steel hinges for welding or screw-fitting
- Integrated door closers
- Multipoint locks (motorized also available)
- Designer glazing beads
- Emergency locks and panic push-bars
Special Technical Features
- Dry glazing or glazing with putty
- Central glazed panel sheet metal clad doors
- Door height up to 2.5 m with single-latch lock
- Door height up to 3.0 m with single-latch lock and bi-metal lug or single-
- latch lock with top retracting bolt or with multipoint locking