Nothing is more rational than using the wind, a natural, free, renewable and healthy resource, to improve the thermal comfort of our projects. The awareness of the finiteness of the resources and the demand for the reduction in the energy consumption has removed air-conditioning systems as the protagonist of any project. Architects and engineers are turning to this more passive system to improve thermal comfort. It is evident that there are extreme climates in which there is no escape, or else the use of artificial systems, but in a large part of the terrestrial surface it is possible to provide a pleasant flow of air through the environments by means of passive systems, especially if the actions are considered during the project stage.

This is a highly complex theme, but we have approached some of the concepts exemplifying them with built projects. A series of ventilation systems can help in the projects: natural cross ventilation, natural induced ventilation, chimney effect and evaporative cooling, which combined with the correct use of constructive elements allows improvement in thermal comfort and decrease in energy consumption.

Natural cross ventilation is when openings in a certain environment or construction are arranged on opposite or adjacent walls, allowing air to enter and exit. Indicated for buildings in climatic zones with higher temperatures, the system allows constant changes of the air inside the building, renewing it and still, considerably reducing the internal temperature.

Taking the Lee House by Studio MK27 uses window frames that allow full opening, when embedded inside the walls, the design solution allowed the volume to have large openings in two walls positioned opposite each other, providing abundant ventilation and causing thermal equilibrium by constant air changes.

Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 3 of 12
Casa Lee / Studio MK27. Image © Fernando Guerra | FG+SG

Induced natural ventilation refers to thermal induction systems are used to conduct air cooling. The warm air is lighter than the cold air, in this case, in an external or internal environment the warm air goes up and the cold air goes down. In this ventilation system, openings are positioned close to the ground so the cold air enters the space by pushing the mass of warm air above, where air outlets are positioned in the ceiling such as sheds and clerestory.

Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 4 of 12
Sarah Kubitschek Hospital Salvador / João Filgueiras Lima. Image © Nelson Kon

An excellent example of this model is the Sarah Kubitschek Hospital in Salvador Brazil, designed by the Brazilian Architect João Filgueiras Lima, who through curved metallic sheds, with large and different extensions, successively repeated, ventilate the environments by the release of warm air and impurities through the upper openings, still guaranteeing natural light. It is worth emphasizing that in projects related to Health, it is avoided the use of systems that appropriate cross ventilation, since it can cause bacteria transmission by the propagation of air.

Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 12 of 12
Reichstag / Norman Foster. Image© Renate Dodell via Flickr Licença CC BY-ND 2.0

In vertical buildings, vertical ventilation flow through the chimney effect is constantly used. Cold air exerts pressure under the warm air forcing it to go up, as well as in induced ventilation. However, in this case, opened areas by the project center or towers allow the same air to circulate through the environment, leaving through the roof, clerestory, zenithal openings or wind exhausts. The dome of the New German Parliament, Reichstag, designed by Norman Foster is an example of this ventilation system. Through a summit with external glass closure and inverted cone with panels mirrored to the center allows air circulation in the building, which is released by the opening at the top.

Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 10 of 12
Estratégias bioclimáticas do Edifício da Empresa de Desenvolvimento Urbano (EDU) em Medellin. Image Cortesia de EDU
Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 11 of 12
Building of the Urban Development Company (EDU) in Medellin. Image © Alejandro Arango

In the construction of the new Urban Development Company (EDU) headquarters in Medellin, an outer skin composed of high-quality prefabricated elements allows conduct to an internal solar chimney to refresh the outside cold air. This is done with simple materials that generate thermal mass control and thermodynamic concepts - convex and thermal forces - generating a change in the temperature of the constant fluid air, from the cold to the warm one, creating air currents in the workspaces.

Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 2 of 12
Palácio da Assembléia de Chandigarh / Le Corbusier. Image © Laurian Ghinitoiu

The evaporative cooling system, used in Le Corbusier's work in Chandigarh and Oscar Niemeyer's work in Brasilia, uses the availability of large water mirrors or lakes, strategically positioned towards predominant air currents, in front of buildings with openings, after floating above the water the wind follows with a certain percentage of humidity, guaranteeing freshness to arid climates.

In addition to ventilation systems, constructive mechanisms should also be considered. 

Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 8 of 12
Ventilation by Brise Soleil Diagram. Image © Matheus Pereira

Brises Soleil or sun breakers are excellent mechanisms to guarantee natural ventilation, which in addition to light and solar control if properly designed and positioned in conjunction with solar and local wind conditions, can guarantee excellent internal thermal quality. They also allow control, if furniture, or even in case of leaked elements (cobogos, perforated plates, mashrabiyas, among others) causes direct ventilation with the possibility of calculation in percentage according to the size of the openings. 

Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 7 of 12
Windows Openings Diagram. Image © Matheus Pereira

The consideration of the types of openings is indispensable. In a practical way, let us think of an environment that, if a window with two sheets of sliding glass is chosen, it is understood that when opening, only 50% of the opening will allow the wind to enter. With the same size of the span, if we opt for a window with one or two open sheets, the ventilation will be integral. Depending on the type of window, seal or door chosen, it will directly influence the direction of the winds (vertical, horizontal or inclined) and percentage of the inward air mass. 

Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation - Image 9 of 12
Ventilation diagram. Image © Matheus Pereira

Barriers should also be considered. Think of an environment with a double ceiling height, an opening (door) in the lower area and two other openings (windows) positioned on the opposite wall in the middle and highest point, and in the center, a half-height wall. Of course, the central wall will act as a barrier and mandate the direction of the winds. Other constructive elements may help in solving the problem, such as the replacement of masonry with perforated bricks - cobogos.

The different heights of the openings and barriers (walls, sill, panels or furniture) arranged by the space also directly influence the level and speed of ventilation levels. In each project, attention should be paid to their arrangement according to the type and level of ventilation required.

References

  • ABNT 15.575. Guia para arquitetos na aplicação da Norma de Desempenho. Available here. Acessed on December 31, 2017.
  • GIVONI, Baruch. Climate Considerations in Building and Urban Design. New York: Van Nostrand Reinhold, 1998.
  • ROMERO, Marta Adriana Bustos. Princípios bioclimáticos para o desenho urbano. 2ª ed. São Paulo: Pro E, 2000.
  • VAN LENGEN, Johan. Manual do arquiteto descalço. 1ª ed. São Paulo: B4 Editores, 2014. p.46-53.

Note: Originally published on January 21, 2018, and updated on January 9, 2020.

About this author
Cite: Pereira, Matheus. "Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation" [Ventilação cruzada? Efeito chaminé? Entenda alguns conceitos de ventilação natural ] 05 Apr 2020. ArchDaily. (Trans. Carvalho, Guilherme) Accessed . <https://www.archdaily.com/887460/cross-ventilation-the-chimney-effect-and-other-concepts-of-natural-ventilation> ISSN 0719-8884

Sarah Kubitschek Hospital Salvador / João Filgueiras Lima. Image © Nelson Kon

什么是贯流通风?什么是烟囱效应?深度解答众多“通风”概念

You've started following your first account!

Did you know?

You'll now receive updates based on what you follow! Personalize your stream and start following your favorite authors, offices and users.